Specification
Model | Joint Width (mm.) | Depth of Seal (mm.) | Movement Capacity (mm.) | Movement Opening Min-Max (mm.) | Fire-Rated (Hr.) |
DFR2-0100 | 25 | 100 | ± 12.50 | 12.50-37.50 | 2 |
DFR 2-0150 | 40 | 100 | ± 20 | 20.00-60.00 | 2 |
DFR2-0175 | 45 | 100 | ± 22.50 | 22.50-67.50 | 2 |
DFR2-0200 | 50 | 100 | ± 25 | 25.00-75.00 | 2 |
Material : Pre formed closed cell with traffic-grade silicone (Top) and fire-retardant (Bottom)
Color system : Grey
Installation characteristics : Epoxy adhesive
Special Features
- 2-Hour Fire Rated to UL 2079
- Meets the requirements of ASTM E1966, ASTM E119 and ASTM E1399
- One Install Does It All–fire-rated, watertight, traffic bearing, 100% movement, quiet, non-invasive anchoring, UL 2079 Certified for decks and floors